Beltéri vízhűtéses folyadékhűtők és hőszivattyúk

A víz bajnokai

A vízhűtéses kondenzátorral rendelkező GWC és GLWC folyadékhűtők felépítése sokkal kompaktabb, mint a léghűtéses kiviteleké. Kizárólag beltéri kivitelben készülnek, és optimálisan helyezhetők el bármilyen gépházban vagy hőközpontban.

  •  

    GLWC 1055 – 2475 DA2 (190 - 1700 kW)

    General:

    - Highly efficient model with flooded evaporator
    - Optimized for space-saving configuration

    Refrigeration circuit:

    - High-efficiency optimized model with 1 or 2 screw compressors
    - One screw compressor each per refrigerant circuit for best possible redundancy
    - Screw compressor with continuously variable capacity control for constant water outlet temperatures
    - Electronic expansion valve EEV
    - Shell and tube heat exchanger
    - Electronic pressure sensor for high and low pressure

    Control & regulation:

    - Unit main switch
    - Automatic circuit breakers for all electric consumers
    - Autoadaptive microprocessor control
    - Water inlet or outlet control
    - Automatic self-diagnostics
    - Alphanumeric display
    - Selection of various languages
    - Reading off alarm or error messages
    - Remote on/off contact
    - Collective fault message
    - Operation status message of unit

    Accessories:
    - Master/slave operation with up to 5 units in one hydraulic circuit
    - Connection to the building management system via modbus, LonWorks and BACnet possible
    - Connection of an additional remote control
    - Many further extensive accessories available

    • ErP 2018 ready
    • Indoor installation
    • Screw compressor
    • Cooling
    • Refrigerant R-134a
    • Shell and tube heat exchanger
    • Master/slave operation is possible
    • BMS integration is possible
  •  

    GLWC 2012 – 4120 CD2 (38 - 400 kW)

    General:

    - Model as water-cooled chiller
    - Space-saving under consideration of optimal service access

    Refrigeration circuit:

    - Depending on capacity stage, the units have 1-2 refrigeration circuits
    - Equipped with 2 or 4 scroll compressors in tandem design
    - Electronic expansion valve EEV
    - Plate heat exchanger
    - Electronic pressure sensor for high and low pressure

    Hydraulics:

    - Optional hydraulic module for chilled water and heat-rejection water circuit with standard or inverter pump
    - Water pumps available in two power output levels
    - 1 or 2 water pumps for redundant operation with with automatically timed switch-over or in the event of a pump malfunction
    - Water filter and flow monitor available as accessories

    Control & regulation:

    - Unit main switch
    - Automatic circuit breakers for all electric consumers
    - Autoadaptive microprocessor control
    - Water inlet or outlet control
    - Automatic self-diagnostics
    - Alphanumeric display
    - Selection of various languages
    - Reading off alarm or error messages
    - Remote on/off contact
    - Collective fault message
    - Operation status message of unit

    Accessories:

    - Master/slave operation with up to 5 units in one hydraulic circuit
    - Connection to the building management system via modbus, LonWorks and BACnet possible
    - Connection of an additional remote control
    - Many further extensive accessories available

    • Variable Pump Speed
    • Electronic Expansion Valve
    • ErP 2021 ready
    • Indoor installation
    • Scroll compressor
    • Cooling
    • Refrigerant R-410A
    • Plate heat exchanger
    • Master/slave operation is possible
    • BMS integration is possible
  •  

    GLWH 2012 – 4120 CD2.H (38 - 400 kW)

    General:

    - Model as water/water heat pump
    - Space-saving under consideration of optimal service access

    Refrigeration circuit

    - Depending on capacity stage, the units have 1-2 refrigeration circuits
    - Equipped with 2 or 4 scroll compressors in tandem design
    - Electronic expansion valve EEV
    - Plate heat exchanger
    - Electronic pressure sensor for high and low pressure

    Control & regulation:
    - Unit main switch
    - Automatic circuit breakers for all electric consumers
    - Autoadaptive microprocessor control
    - Water inlet or outlet control alternatively for evaporator or condenser
    - Automatic self-diagnostics
    - Alphanumeric display
    - Selection of various languages
    - Reading off alarm or error messages
    - Remote on/off contact
    - Collective fault message
    - Operation status message of unit

    Accessories:
    - Master/slave operation with up to 5 units in one hydraulic circuit
    - Connection to the building management system via modbus, LonWorks and BACnet possible
    - Connection of an additional remote control
    - Many further extensive accessories available

    • Variable Pump Speed
    • Electronic Expansion Valve
    • ErP 2021 ready
    • Refrigerant R-410A
    • Cooling
    • Heating
    • Indoor installation
    • Scroll compressor
    • Plate heat exchanger
    • Master/slave operation is possible
    • BMS integration is possible
  •  

    GLWH 2012 – 4120 CD2.R (38 - 400 kW)

    General:

    - Model as water/water heat pump with reversible refrigeration circuit
    - Space-saving under consideration of optimal service access

    Refrigeration circuit

    - Depending on capacity stage, the units have 1-2 refrigeration circuits
    - Equipped with 2 or 4 scroll compressors in tandem design
    - Electronic expansion valve EEV
    - 4-way switching valve to switch over the refrigerant circuit
    - Plate heat exchanger
    - Electronic pressure sensor for high and low pressure

    Hydraulics:
    - Optional hydraulic module for chilled water and heat-rejection water circuit with standard or inverter pump
    - Water pumps available in two power output levels
    - 1 or 2 water pumps for redundant operation with with automatically timed switch-over or in the event of a pump malfunction
    - Water filter and flow monitor available as accessories

    Control & regulation:

    - Unit main switch
    - Automatic circuit breakers for all electric consumers
    - Autoadaptive microprocessor control
    - Water inlet or outlet control
    - Automatic self-diagnostics
    - Alphanumeric display
    - Selection of various languages
    - Reading off alarm or error messages
    - Remote on/off contact
    - Collective fault message
    - Operation status message of unit

    Accessories:

    - Master/slave operation with up to 5 units in one hydraulic circuit
    - Connection to the building management system via modbus, LonWorks and BACnet possible
    - Connection of an additional remote control
    - Many further extensive accessories available

    • Variable Pump Speed
    • Electronic Expansion Valve
    • ErP 2021 ready
    • Indoor installation
    • Scroll compressor
    • Cooling
    • Heating
    • Refrigerant R-410A
    • Plate heat exchanger
    • Master/slave operation is possible
    • BMS integration is possible
  •  

    GLWH 1130 – 4960 CA2.HT (345 – 2581 kW)

    Equipment:

    • HT version with 1, 2, 3 or 4 screw compressors
    • One screw compressor per refrigerant circuit for best possible redundancy
    • Screw compressor with continuously variable capacity control
    for constant water outlet temperature
    • Expanded operating limits to 60 °C warm water outlet temperature
    • Control cabinet on the front side
    • Pump enabling as an option
    • Selectable regulation of condenser water temperature (warm water) and evaporator water temperature (chilled water)
    • Autoadaptive microprocessor control
    • Unit main switch
    • Automatic circuit breakers for all electric consumers
    • Configuration with an electronic expansion valve EEV
    • Controller: HVAC systems Step III
    • Master/slave operation with HVAC System unit series available as an accessory item
    • Connection to BMS via optional interface

    • Indoor installation
    • Screw compressor
    • Cooling
    • Heating
    • Refrigerant R-134a
    • Shell and tube heat exchanger
    • Master/slave operation is possible
    • BMS integration is possible
    • Unit as high-temperature model

Ezek a berendezések kis és közepes teljesítmény tartományban  lemezes hőcserélőt használnak mind elpárologtatóként, mind kondenzátorként. A nagyobb készülékek (2.790 kW teljesítményig) csőköteges hőcserélővel rendelkeznek.

A készülékeket már a zajkibocsátási jellemzőket is figyelembe véve tervezték. Ezen túlmenően egyes típusok szállíthatók kiegészítő hangcsillapító burkolattal is, ami meggátolja a zavaró hangok terjedését az épület belsejében. Közepes és nagyobb teljesítmény tartományban a berendezések hőszivattyúként is rendelhetők.

Kapcsolatfelvétel

DencoHappel Austria GmbH

Magyarországi Fióktelepe
1117. Budapest, Irinyi József utca 4-20. Science Park "B" épület
Hungary
+36 (1) 439 3200
+36 (1) 439 3219
Alkalmazási területek

Folyadékhűtők:

  • GLWC 0152 – 0612 BD2
  • GLWC 0524 – 1204 BD2
  • GLWC 0401 – 0961 BA2
  • GLWC 0802 – 1902 BA2
  • GLWC 1130 – 4960 CA2

Hőszivattyúk:

  • GLWH 0152 – 0612 BD2
  • GLWH 0524 – 1204 BD2
  • GLWH 0401 – 0961 BA2
  • GLWH 0802 – 1902 BA2
  • GLWH 1130 – 4960 CA2